| KyteLabs InfoBase - Electron Tubes & Valves Data | Last modified: 2024-10-01 (21517) |
| 1 | Anhang Appendix |
| A.2 | Hinweise und Bemerkungen Notes and Remarks |
| A: | Klasse-A-Betrieb. |
|---|---|
| Class-A operating mode. | |
| Amplificateur, classe A. | |
| A1: | Klasse-A1-Betrieb (ohne Gitterstrom). |
| Class-A1 operating mode (without grid current). | |
| Amplificateur, classe A1 (sans courant de grille). | |
| A2: | Klasse-A2-Betrieb (mit Gitterstrom). |
| Class-A2 operating mode (with grid current). | |
| Amplificateur, classe A2 (avec courant de grille). | |
| AB: | Klasse-AB-Betrieb. |
| Class-AB operating mode. | |
| Amplificateur, classe AB. | |
| AB1: | Klasse-AB1-Betrieb (ohne Gitterstrom). |
| Class-AB1 operating mode (without grid current). | |
| Amplificateur, classe AB1 (sans courant de grille). | |
| AB2: | Klasse-AB2-Betrieb (mit Gitterstrom). NF-Verstärker oder HF-Linearverstärker. |
| Class-AB2 operating mode (with grid current). AF Amplifier or RF Linear Amplifier | |
| Amplificateur, classe AB2 (avec courant de grille). | |
| ABS: |
Absolute Grenzwerte |
|
Absolute Maximum Ratings | |
| Système des limites absolues | |
| ABS: |
Der angegebene Wert muss als absoluter Grenzwert betrachtet werden. |
|
Value given is to be considered as an Absolute Maximum Rating. | |
| Système des limites absolues | |
| AC: | Wechselspannungsheizung. |
| AC operated filament. | |
| Chauffage par courant alternativ. | |
| AC/DC: | Wechsel- oder Gleichspannungsheizung. |
| AC or DC operated filament. | |
| Chauffage par courant alternativ ou continu. | |
| AC/DC Uf: | Maximale Heizspannung bei Betrieb am Wechselstrom- oder Gleichstrom-Netz (Nominalgrenzwert). |
| Maximum Filament Voltage at AC/DC Power Line Operation - Design Center. | |
| - | |
| A-GG: | Klasse-A Linearverstärker in Gitterbasis-Schaltung mit Katodenansteuerung. |
| Class-A Grounded-Grid Linear Amplifier with Cathode Drive. | |
| - | |
| B: | Klasse-B Niederfrequenzverstärker. |
| Class-B Audio-Frequency Power Amplifier. | |
| Amplificateur B.F., classe B. | |
| B1: | Klasse-B1-Betrieb (ohne Gitterstrom). |
| Class-B1 operating mode (without grid current). | |
| Amplificateur, classe B1 (sans courant de grille). | |
| B2: | Klasse-B2-Betrieb (mit Gitterstrom). |
| Class-B2 operating mode (with grid current). | |
| Amplificateur, classe B2 (avec courant de grille). | |
| B-GG: | Klasse-B Linearverstärker in Gitterbasis-Schaltung mit Katodenansteuerung. |
| Class-B Grounded-Grid Linear Amplifier with Cathode Drive. | |
| Amplificateur linéaire H.F. classe B, à commande par cathode, grille mise à la terre. | |
| B-RF: | Klasse-B Hochfrequenzverstärker, Telefonie. Modulierter Träger als Eingangssignal. |
| Class-B Radio-Frequency Power Amplifier, Telephony. Modulated carrier applied to the grid. | |
| Amplificateur H.F. classe B téléphonie. | |
| B-SSB: | Klasse-B Hochfrequenz-Linearverstärker, Einseitenbandverstärker. |
| Class-B Radio-Frequency Linear Amplifier, Single-Side-Band Amplifier. | |
| Amplificateur linéaire H.F. classe B, à une bande latérale. | |
| C: | Klasse-C Hochfrequenzverstärker oder Oszillator, Telegrafie oder FM. |
| Class-C telegraphy or FM operating mode, radio-frequency amplifier or oscillator. | |
| Amplificateur H.F. classe C, télégraphie ou F.M. téléphonie, ou oscillatrice. | |
| C2F: | Klasse-C Frequenzverdoppler. |
| Class-C Frequency Doubler. | |
| Classe C doubleur de fréquence. | |
| C3F: | Klasse-C Frequenzverdreifacher. |
| Class-C Frequency Tripler. | |
| Classe C tripleur de fréquence. | |
| C4F: | Klasse-C Frequenzvervierfacher. |
| Class-C Frequency Quadrupler. | |
| Classe C quadrupleur de fréquence. | |
| CCS: |
Kommerzieller Dauerbetrieb. |
|
Continuous Commercial Service. | |
| Service continu. | |
| CCS: |
Absolute Grenzwerte CCS = Kommerzieller Dauerbetrieb. |
|
Absolute Maximum Ratings CCS = Continuous Commercial Service. | |
| Limites absolues en service continu. | |
| CCS: |
Nominalgrenzwerte CCS = Kommerzieller Dauerbetrieb. |
|
Design Centre Ratings CCS = Continuous Commercial Service. | |
| Limites moyennes en service continu. | |
| CEN: |
Nominalgrenzwerte. |
|
Design Centre Ratings. | |
| Système des limites moyennes | |
| CEN: |
Der angegebene Wert ist Nominalgrenzwert. |
|
Value given is Design Centre Rating. | |
| Système des limites moyennes. | |
| C-GG: | Klasse-C HF-Verstärker in Gitterbasis-Schaltung mit Katodenansteuerung. |
| Class-C Grounded-Grid RF Amplifier with Cathode Drive. | |
| Amplificateur H.F. classe C, à commande par cathode, circuit "grounded-grid" grille mise à la terre. | |
| C-In: | Kondensator am Filtereingang (CkL). |
| Capacitor Input Filter (CkL). | |
| Condensateur à l'entrée du filtre (CkL). | |
| CXF: | Klasse-C Frequenzvervielfacher (Verdoppler, Verdreifacher). |
| Class-C Frequency Multiplier (Doubler, Tripler). | |
| Classe C multiplicatrice de fréquence (doubleur, tripleur) | |
| DC: | Gleichspannungsheizung. |
| DC operated filament. | |
| Chauffage par courant continu. | |
| E: | Tetrodensystem (E). |
| Applies to tetrode section (E). | |
| - | |
| F: | Pentodensystem (F). |
| Applies to pentode section (F). | |
| - | |
| Gas: | Füllgas: Ar = Argon, H2 = Wasserstoff, He = Helium, Hg = Quecksilberdampf, Inert = Edelgase, Ne = Neon, Xe = Xenon. |
| Gas filling: Ar = argon, H2 = hydrogen, He = helium, Hg = mercury vapor, Inert = inert gases, Ne = neon, Xe = xenon. | |
| Remplissage de gaz: Ar = argon, H2 = hydrogène, He = hélium, Hg = vapeur de mercure, Inert = gaz nobles, Ne = néon, Xe = xénon. | |
| GC: | Katodenbasis-Schaltung mit Gitteransteuerung. |
| Grounded-Cathode Circuit with Grid Drive. | |
| - | |
| GG: | Gitterbasis-Schaltung mit Katodenansteuerung. |
| Grounded-Grid Circuit with Cathode Drive. | |
| - | |
| H11: |
Mit normierter Anheizzeit tf = 11 Sekunden im Mittel. |
|
Controlled heater warm-up characteristic with average warm-up time tf = 11 seconds. | |
| - | |
| I: | System I. |
| Applies to section No.1. | |
| Section n° 1. | |
| I+II: | Beide Systeme parallelgeschaltet. |
| Both sections are connected in parallel. | |
| - | |
| ICAS: |
Intermittierender (unterbrochener) kommerzieller und Amateurfunkbetrieb. |
|
Intermittent Commercial and Amateur Service. | |
| Service intermittent. | |
| ICAS: |
Absolute Grenzwerte ICAS = Intermittierender (unterbrochener) kommerzieller und Amateurfunkbetrieb. |
|
Absolute Maximum Ratings ICAS = Intermittent Commercial and Amateur Service. | |
| Limites absolues en service intermittent. | |
| ICAS: |
Nominalgrenzwerte ICAS = Intermittierender (unterbrochener) kommerzieller und Amateurfunkbetrieb. |
|
Design Centre Ratings ICAS = Intermittent Commercial and Amateur Service. | |
| Limites moyennes en service intermittent. | |
| II: | System II. |
| Applies to section No.2. | |
| Section n° 2. | |
| III: | System III. |
| Applies to section No.3. | |
| Section n° 3. | |
| IMS: |
Intermittierender (unterbrochener) Mobilbetrieb. |
|
Intermittent Mobile Service. | |
| - | |
| IMS: |
Absolute Grenzwerte IMS = Intermittierender (unterbrochener) Mobilbetrieb. |
|
Absolute Maximum Ratings IMS = Intermittent Mobile Service. | |
| - | |
| L: | Pentodensystem (L). |
| Applies to pentode section (L). | |
| - | |
| LC: | Kann als Lötstützpunkt für Bauteile benutzt werden, die nahe oder bei Anoden- bzw. Schirmgittergleichspannung arbeiten. In anderen Fällen darf der Anschluss nicht verwendet werden. |
| May be used as tie point for components operating at or near the DC voltage of either the grid No.2 or plate, or between thes voltages. Otherwise, do not use. | |
| - | |
| L-In: | Drossel am Filtereingang (LkL). |
| Choke Input Filter (LkL). | |
| Inductance à l'entrée du filtre (LkL) | |
| LOAD: | Minimaler Laststrom zur Bewahrung der optimalen Spannungsstabilität mit der angegebenen Filterdrossel LkL. |
| Minimum Load Current to maintain optimum regulation with rated choke inductance LkL. | |
| - | |
| M: | Anzeigesystem - 'Magisches Auge' (M). |
| Applies to 'Magic Eye' display section (M). | |
| - | |
| MAX: |
Toleranzgrenzwerte. |
|
Design Maximum Ratings. | |
| Système des limites hybrides | |
| MAX: |
Der angegebene Wert ist Toleranzgrenzwert. |
|
Value given is Design Maximum Rating. | |
| Système des limites hybrides | |
| OUT: | Zur Verwendung als Endröhre. |
| For use as output tube. | |
| Pour utilisation comme tube de sortie. | |
| PP: | Betrieb in Gegentaktschaltung. |
| Push-Pull Operation. | |
| - | |
| PRE: | Zur Verwendung als Vorverstärker. |
| For use as pre-amplifier. | |
| Pour utilisation en pré-amplificateur. | |
| RA: | Zur Vermeidung grösserer Zündspannungsschwankungen durch Beleuchtungsunterschiede ist auf der Innenwand des Kolbens radioaktives Material (Ring) aufgebracht. |
| To avoid larger fluctuations of ignition voltage due to changing illumination, the inner bulb surface is coated with a ring of radioactive material. | |
| - | |
| RC: | RC-gekoppelter Verstärker. |
| Resistance Coupled Amplifier. | |
| - | |
| SOA: | Grenzkurven "Sicherer Arbeitsbereich". |
| "Safe Operating Area" Rating Chart. | |
| - | |
| SSB1: | Typischer Betrieb als HF-Linearverstärker, Einseitenband (SSB) mit unterdrücktem Träger und Einzelton-Aussteuerung. |
| Typical operation as Linear RF Power Amplifier for Single-Sideband Suppressed-Carrier Service and "Single-Tone Modulation". | |
| - | |
| SSB2: | Typischer Betrieb als HF-Linearverstärker, Einseitenband (SSB) mit unterdrücktem Träger und Doppelton-Aussteuerung. Der Wert der Ausgangsleistung beim Scheitelwert der Hüllkurve (PEP) gilt für Signalbedingungen, bei denen das Verhältnis Spitzenleistung zu mittlerer Leistung mindestens 2 ist. |
| Typical operation as Linear RF Power Amplifier for Single-Sideband Suppressed-Carrier Service and "Two-Tone Modulation". Power Rating at Peak of Envelope (PEP) with peak envelope conditions for a signal having a minimum peak-to-average power ratio of 2. | |
| - | |
| T: | Triodensystem. |
| Applies to triode section. | |
| - | |
| TC: | Transformatorgekoppelter Verstärker. |
| Transformer Coupled Amplifier. | |
| - | |
| TV-GG: | Modulierte TV-Endstufe in Gitterbasis-Schaltung (Synchronpegel). |
| Modulated Grounded-Grid TV Power Amplifier (Sync Level). | |
| - | |
| TYP: | Typische Betriebswerte. |
| Typical operating conditions. | |
| - | |
| UL: | Ultralinear-Schaltung. |
| Ultra-Linear Circuit. | |
| - | |
| V: | TV Vertikalablenkung. |
| TV Vertical Deflection Amplifier. | |
| VP: | TV Vertikalablenkung in Pentodenschaltung. |
| TV Vertical Deflection Amplifier (Pentode Circuit). | |
| VT: | TV Vertikalablenkung in Triodenschaltung. |
| TV Vertical Deflection Amplifier (Triode Connection). | |